// Language switcher on every page: EN default navI18n unless a locale // page supplied its own. Non-translatable paths link the menu to each homepage. const navI18n = options.navI18n || (() => { const L = uiFor('en'); const m = (options.seoHeadTags || '').match(/rel="canonical" href="([^"]+)"/); const path = m ? m[1].replace(/^https?://[^/]+/, '') : '/'; const translatable = TRANSLATED_PATHS.some(re => re.test(path)); const entries = [{ code: 'en', host: 'hengxang.com', name: 'English' }, ...LOCALES]; return { t: L, currentName: 'English', path, langItems: entries.filter(e => e.code !== 'en') .map(e => '
  • ' + e.name + '
  • ').join(''), }; })();

    Fiber Optic Attenuator Manufacturer

    HENGXANG builds fiber optic attenuators in Yiwu, Zhejiang - fixed plug-in types from 1 dB to 30 dB and variable VOA models from 0 dB to 60 dB, in SC, LC, FC and ST interfaces, single-mode and multimode. The factory has produced passive optical hardware since December 2000, and every attenuator batch reads its dB value on a calibrated power meter before packing.

    Buyers use these attenuators where a link runs too hot - the everyday work of a fiber optic attenuator manufacturer with its own test bench: receiver saturation on short FTTH runs, CATV optical level trimming, DWDM channel balancing and lab power budgets. An attenuator is a measured component - the value on the body must match the value on the meter, and that is exactly what this fiber optic attenuator manufacturer tests for, piece by batch.

    This page from a certified fiber optic attenuator manufacturer lists the attenuator families with MOQ and lead time, explains fixed versus variable, shows the OEM program, certifications and factory facts - then the questions buyers ask first. Send your dB values and the export desk replies with a written quote within 24 hours on business days.

    ホーム / 製品 / Fiber Optic Attenuator

    Fiber Optic Attenuator Products

    Attenuator Families: Specs, MOQ and Lead Time

    Every attenuator family this fiber optic attenuator manufacturer builds is listed below with MOQ and lead time. Lead time runs from deposit and includes dB verification testing on calibrated power meters.

    FamilyOptionsMOQLead time
    SC fixed plug-inUPC / APC, 1-30 dB standard steps, SM500 pcs5-8 days
    LC fixed plug-inUPC / APC, 1-30 dB, SM500 pcs5-8 days
    FC / ST fixedMetal body, UPC, SM500 pcs6-9 days
    Multimode fixed50/125 and 62.5/125, 850 nm, 1-30 dB500 pcs5-8 days
    Variable VOASC, LC, FC - 0-30 dB or 0-60 dB adjustment200 pcs7-10 days
    In-line attenuators0.9-3.0 mm cable, any connector pair500 pcs6-9 days

    MOQ and lead-time figures are standard production windows; Chinese New Year peaks can add 5-7 days. Fixed delivery dates are confirmed in writing on the proforma invoice.

    What buyers order most from this shelf

    These five cover most purchase orders. Every dB value in the standard ladder builds to your connector type and polish - the full shelf sits in the product grid above.

    Why Links Need Attenuation: Four Real Situations

    An attenuator solves a problem most buyers meet within the first year of operating a network - and choosing the right fiber optic attenuator manufacturer decides whether the dB value on the label is real:

    The common thread: attenuation is applied on purpose, by a measured amount from a fiber optic attenuator manufacturer that verifies every batch. That is why a fiber optic attenuator manufacturer sells numbers, not just hardware - the value printed on the body is the product.

    Fixed vs Variable: Choosing by Application

    Both families sit on this shelf - the core range of a fiber optic attenuator manufacturer, and the choice follows the stability of your power budget - the guidance a fiber optic attenuator manufacturer gives on every quote:

    Fixed plug-inVariable VOA
    ValueOne dB value, set at the factoryAdjustable 0-30 or 0-60 dB
    Accuracy+/-0.5 dB (draft)0.2 dB graduation on the dial
    RepeatableYes - passive, no moving partsRepeatability depends on the dial
    Best forPermanent links, closures, panelsLabs, balancing, commissioning
    Unit costLowerHigher

    Practical rule from installers: fixed everywhere the link is designed once, variable where the power budget is still moving. Many projects buy fixed for the field and a handful of VOAs for the commissioning toolbox.

    Application Notes by Network Type

    Four network types order attenuators for four different reasons, and each pulls a different mix from the shelf:

    Whatever the network, the workflow is identical: measure the surplus, pick the value, verify on the meter. The attenuator is the last step of a calculation, not a guess.

    How Many dB Do You Need? The Power Budget Math

    You can calculate the attenuation value yourself with four numbers from the link datasheet:

    Worked example (illustrative): +3 dBm arrives at the receiver with 4 dB of link loss, so the receiver sees -1 dBm. The ceiling is -8 dBm. The link runs 7 dB hot - a 7 dB attenuator trims it to -8 dBm exactly at the ceiling, and the 2-3 dB reserve argues for the 10 dB step instead. Send us the four numbers and we state the value we would ship - in writing, before the quote.

    Two habits keep the math honest: calculate at the highest-power wavelength, and re-check after amplifier upgrades. Attenuation solves saturation; it never repairs a link that is simply broken.

    How Our Attenuators Are Built and Verified

    Four steps take an attenuator from parts to a labeled, measured component - the verification culture that separates a fiber optic attenuator manufacturer from a parts reseller:

    1. Element preparation: the ion-doped absorbing fiber segment is cut to the length that produces the target dB value at the rated wavelength.
    2. Assembly: the element bonds between two ferrule interfaces in the housing - SC, LC, FC or ST - with the return-loss geometry intact.
    3. Verification: batch testing on a calibrated power meter at 1310 and 1550 nm against a reference; the batch passes only inside the tolerance window.
    4. Marking: the dB value prints or laser-marks on the housing, UPC blue, APC green, so installers read the value at the panel.

    The same test bench discipline runs across the factory - it is the bench our patch cords and connectors pass through, calibrated to the same references.

    Inside Our Variable VOA: Two Dial Styles

    Variable attenuators come in two adjustment styles, and both sit on this shelf:

    Both styles read in 0.2 dB graduations on the dial scale (draft) and hold the set value across the -40°C to +75°C operating band. The adjustment mechanism adds no moving fiber parts - the attenuating element stays fixed.

    PDL and WDL: The Two Specs Serious Buyers Ask For

    Insertion loss tells half the story. The other half lives in two second-order specs that separate precision attenuators from padded plastic:

    Ask any supplier for PDL and WDL numbers in writing. A fiber optic attenuator manufacturer with its own bench answers in the quote; a reseller asks someone else next week.

    OEM, ODM and Private-Label Capability

    As an OEM fiber optic attenuator manufacturer, we build to your dB ladder, marking and packaging spec:

    OEM projects we shipped (draft references - replace with your approved cases)

    “The dB labels matched our power meter on every single sample - acceptance took one afternoon.” - network engineer, European CATV operator (draft testimonial - replace with your approved reference).

    “They built a custom 4 dB value nobody stocks, in two weeks, at a standard-price step.” - purchasing lead, US instrument maker (draft testimonial - replace with your approved reference).

    Attenuators usually ship together with the connectors they mate to and the adapters they seat in - one container covers the whole level-trimming job.

    Certifications and Compliance

    The factory runs under ISO 9001:2015, with CE reports covering passive families sold into the EU, and the company holds a utility patent on a fiber optic quick connector - evidence of the in-house R&D that also designs attenuator builds. Documents are public on the certificate page.

    CertificateRelevance to attenuators
    ISO 9001:2015Quality management for assembly and dB verification
    OHSAS 18001:2007Occupational health and safety management
    CE reportsPassive families shipped into the EU
    Utility model patentQuick connector design - the factory's R&D depth

    RoHS-compliant materials on request; batch test data joins every shipment.

    Factory Strength: Measured Values Need a Real Bench

    A dB value means nothing without the meter behind it. Our attenuator bench sits inside the Yiwu compound that produces cable, connectors and cords - 25 years under founder LING LI, since December 2000:

    Company quick facts
    FoundedDecember 2000, Yiwu City, Zhejiang, China
    FounderLING LI, Founder & General Manager
    FocusAttenuators, connectors, adapters, patch cords, pigtails, cable, splitters, ODFs
    Export markets40+ countries across Asia, the Middle East, Africa, Europe and the Americas
    Response timeQuotes within 24 hours on business days

    Test Labs and Production Lines: Where Values Get Audited

    Attenuator buyers include labs whose whole business is measurement. Our lab program answers the questions a metrology team asks:

    Labs reorder because the values repeat. That sentence is the whole pitch - and it is why this fiber optic attenuator manufacturer treats the power meter as the real production line.

    Why Buyers Pick HENGXANG Over Other Suppliers

    Attenuators are small parts with large consequences. Compare on the points that decide whether the dB value is real:

    FactorHENGXANGTypical trading company
    VerificationBatch power-meter test against calibration referencesSupplier's word
    Value ladderStandard 1-30 dB plus custom values to orderCommon values only
    Sleeve and polishZirconia sleeves, UPC and APC, stated per lineUnstated
    MOQ200-500 pcs; mixed dB values share the runLarge single-value minimums
    Quote speedWithin 24 hours on business daysDays
    RangeAttenuators + connectors + adapters + panels, one orderSingle category

    And one habit worth naming: if your power survey says the link does not need attenuation, we say so - selling a 10 dB pad into a link that needs none loses us nothing today and costs us the re-order.

    How We Work With You: From dB List to Delivered Boxes

    Six steps, all written down:

    How We Verify: The Bench Procedure, Line by Line

    Verification is the product, so here is the exact batch procedure:

    1. Warm and reference: the power meter warms up and zeroes against the reference launch - never measured cold.
    2. Baseline: a master connector pair reads the bench baseline without the attenuator.
    3. Batch read: sample adapters from the batch insert into the reference chain; the meter reads the added loss at 1310 and 1550 nm.
    4. Window check: the reading must sit inside the datasheet tolerance - inside, release; outside, the batch stops and engineering opens the elements.
    5. File: the readings join the batch file, and the file ships with the goods.

    The same five lines run for fixed and variable types - variable units read at three dial positions. This procedure is why our dB labels survive an audit.

    Worked Example: A Level-Trimming Kit for a CATV Node Upgrade

    Illustrative figures - your quote states yours. An operator upgrades 200 nodes and needs a trimming kit per node: 4,000 attenuators across four values:

    StepDetail
    Day 0dB list received: 1,000 pcs each of SC/APC 3, 5, 7 and 10 dB
    Day 1-2Samples of all four values airfreighted for bench verification
    Day 3-8Production: element prep, assembly and housing per value; batches kept separate
    Day 8-9Verification run; each value's readings filed against the reference meter
    Day 10Pack: four value-labeled cartons, one container slot
    Day 11Trucked to Ningbo, FOB; test files and documents within 2 days of sailing

    Eleven days from dB list to labeled cartons - the pace a fiber optic attenuator manufacturer with its own bench can promise in writing.

    The same flow covers mixed-value kits, custom dB ladders and VOA programs - the only variable is the production calendar slot. Buyers who send the dB list today typically hold labeled cartons inside two weeks; buyers who guess at values hold an argument. Choose the first.

    Trim the Level, Then Run the Whole Shelf

    Attenuators from this fiber optic attenuator manufacturer sit in panels next to everything else this factory builds: the connectors and adapters they mate with, the patch cords around the frame, the cable in the route, and the termination boxes and ODFs that hold the panel. Receivers still hot after the splitter? Balance the split with our PLC splitters page, and read the ODF planning guide before the rack layout locks. One purchase order, one freight plan, one warranty conversation.

    Frequently Asked Questions

    What does a fiber optic attenuator do?

    It reduces optical power by a fixed or adjustable amount. Receivers saturate when a link runs too hot - error rates climb exactly because the signal is too strong. An attenuator adds a measured loss, for example 5 dB, so the receiver sees the power level it was designed for.

    What is your MOQ for attenuator orders?

    Fixed plug-in attenuators start at 500 pieces per dB value, and variable VOA models at 200 pieces. Mixed dB values count toward one production run, so a 3/5/7/10 dB kit for a project ships as one order. Trial quantities ship for labs and first evaluations.

    How accurate are your fixed attenuators?

    Fixed attenuators hold their value within +/-0.5 dB at 1310 nm and 1550 nm (draft tolerance - per-type datasheets carry the binding window). Each batch tests on a power meter against a calibrated reference, and the readings ship with the goods. Accuracy is the product - a 5 dB attenuator that reads 6.2 dB is not a 5 dB attenuator.

    When should I choose a fixed attenuator instead of a variable one?

    Fixed suits permanent links with a known power surplus - a 10 dB plug-in set once and forgotten. Variable VOA suits test benches, DWDM channel balancing and any link whose power budget moves. Variable costs more per piece; fixed wins on every static application.

    Which dB values are standard?

    Standard steps run 1, 2, 3, 5, 7, 10, 15, 20 and 30 dB for fixed types, and 0-30 dB or 0-60 dB adjustment ranges for variable VOA models. Custom values build to order with a small price step. CATV projects usually ask for a value set around the receiver input window.

    Do attenuators work on single-mode and multimode?

    Yes. Single-mode versions cover 1310/1550 nm windows, and multimode versions cover 50/125 and 62.5/125 fiber for 850 nm links. State the fiber type and wavelength when you request the quote - attenuation values differ between windows, and we confirm the match in writing.

    What connector types do your attenuators come in?

    Plug-in attenuators come in SC, LC, FC and ST, in UPC and APC polish, male-to-female style. In-line versions terminate on 0.9 mm to 3.0 mm cable with any connector pair. Variable VOA models come in SC, LC and FC with an adjustment screw or barrel.

    Can one attenuator cover multiple wavelengths?

    Yes - our attenuators are specified at both 1310 nm and 1550 nm, and doped-fiber elements keep the value flat across the window. The batch file lists the reading at both wavelengths, so one part serves dual-window designs.

    Do attenuators affect return loss?

    A well-built attenuator keeps return loss at 50 dB or higher on UPC and 60 dB on APC - the absorbing element adds forward loss without creating a reflective surface. Cheap air-gap types can reflect; that is one reason we build on doped fiber.

    How does a fixed attenuator work inside?

    The attenuation element is a segment of ion-doped absorbing fiber - it absorbs light evenly across the wavelength window instead of reflecting it. That design keeps return loss high and adds almost no distortion. Air-gap types exist, but doped-fiber builds hold their value far better across temperature.

    What Cheap Attenuators Get Wrong

    Field engineers meet the same four defects on bargain attenuators, and each traces to a skipped factory step:

    None of these defects shows in a product photo. All of them show on a power meter in the first week - which is why samples ship free and why the bench evidence belongs in the quotation.

    Storage and Maintenance: Attenuators Are Set-and-Forget, With One Exception

    Fixed attenuators are passive and sealed - installed correctly, they run for decades with no maintenance. Two situations bring them out of the panel:

    Variable VOAs need one extra check: the dial value after any bump or panel move. A 30-second meter read confirms the setting held.

    Packing and Labels

    Standard packing: 100 pieces per PE bag with a type-and-value label, 10 bags per export carton, desiccant included. Custom packing - blister cards, tube packaging for in-line types, or your barcode layout - runs from 2,000 pieces. Every label states the dB value, connector type, polish and sleeve, so a warehouse sorts attenuators without opening a bag.

    Get Your Fiber Optic Attenuator Quote Today

    Send your dB values, connector types and quantities. Your quote with prices, MOQ, lead time and packing plan arrives within 24 hours on business days. Free samples for your power meter - verify the dB values on your own bench before the purchase order, exactly as we do on ours. Custom dB values and mixed-value kits are welcome.

    Request a Quote Now

    WhatsApp: +86 134 3434 9304  |  Email: peter@hengxang.com

    Contact By Whatsapp